Hier werden die Unterschiede zwischen zwei Versionen angezeigt.
Beide Seiten der vorigen Revision Vorhergehende Überarbeitung Nächste Überarbeitung | Vorhergehende Überarbeitung Nächste Überarbeitung Beide Seiten der Revision | ||
projects [2022/08/15 05:41] 167.114.64.97 alte Version wiederhergestellt (2021/12/10 08:42) |
projects [2024/04/26 07:28] 2001:41d0:d:2ab7::1 alte Version wiederhergestellt (2022/01/20 02:34) |
||
---|---|---|---|
Zeile 1: | Zeile 1: | ||
======Projects====== | ======Projects====== | ||
- | A folder with subfolders which includes a set of xml-files to describe what to do with a dataset (session, a set of trials, typcially with c3d-files) is called a " | + | A folder with subfolders which includes a set of xml-files to describe what to do with a dataset (session, a set of trials, typcially with c3d-files) is called a " |
=====PiGMo10 Vicon PiG based===== | =====PiGMo10 Vicon PiG based===== | ||
Zeile 50: | Zeile 50: | ||
=====PiG with functional knee joint axes only ===== | =====PiG with functional knee joint axes only ===== | ||
- | This project adds functional knee joint axes determination (SARA) only to the default Vicon PlugInGait model. It works together with the old Vicon Workstation system and allows to control the usage of the motion phases which are used for the estimation by setting of events. | + | This project adds functional knee joint axes determination (SARA) only to the default Vicon PlugInGait model. It works together with the old Vicon Workstation system and allows to control the usage of the motion phases, which are used for the estimation by setting of events. |
In the gait trials the lateral knee markers are projected onto the functional knee joint axes and the knee joint center is determined based on the clinical measurement of the knee width. Than the femur coordinate system is constructed equivalent to the original PiG. Keep in mind that this coordinate system does not have the functional axis as one of its axes. The axes are defined by cross products and have the longitudinal femur axes included. | In the gait trials the lateral knee markers are projected onto the functional knee joint axes and the knee joint center is determined based on the clinical measurement of the knee width. Than the femur coordinate system is constructed equivalent to the original PiG. Keep in mind that this coordinate system does not have the functional axis as one of its axes. The axes are defined by cross products and have the longitudinal femur axes included. | ||
+ | |||
+ | The proximal tibia (anatomical) coordinate systems are defined by PiG virtual markers. | ||
==== Preconditions ==== | ==== Preconditions ==== | ||
Zeile 84: | Zeile 86: | ||
$RKneeWidth = 104 | $RKneeWidth = 104 | ||
</ | </ | ||
+ | |||
+ | ==== Output ==== | ||
+ | |||
+ | In the default configuration the output is written into " | ||
+ | |||
+ | Hip- and knee-angles are saved to its corresponding PiG angles with the same names but based on the functional knee joint axes. | ||
+ | |||
+ | ^ Name ^ Description ^ | ||
+ | ^ R/ | ||
+ | ^ R/ | ||
+ | |||