Hier werden die Unterschiede zwischen zwei Versionen angezeigt.
Beide Seiten der vorigen Revision Vorhergehende Überarbeitung Nächste Überarbeitung | Vorhergehende Überarbeitung Nächste Überarbeitung Beide Seiten der Revision | ||
projects [2022/01/15 08:17] 192.99.36.166 alte Version wiederhergestellt (2021/10/15 07:40) |
projects [2024/04/18 03:59] 47.128.28.110 alte Version wiederhergestellt (2024/03/21 12:53) |
||
---|---|---|---|
Zeile 1: | Zeile 1: | ||
- | ======PiGMo10 Vicon PiG based====== | + | ======Projects====== |
+ | A folder with subfolders which includes a set of xml-files to describe what to do with a dataset (session, a set of trials, typcially with c3d-files) is called a " | ||
+ | =====PiGMo10 Vicon PiG based===== | ||
This is a clone of what the PiGMo10 " | This is a clone of what the PiGMo10 " | ||
Zeile 8: | Zeile 10: | ||
The lower body kinematics angles of this project are described [[http:// | The lower body kinematics angles of this project are described [[http:// | ||
- | ======PiGMo10 independent====== | + | =====PiGMo10 independent===== |
Additional to the above this also includes a Vicon PiG kinematics clone. This makes the project completly independent from Vicon codebase, for full flexibility. | Additional to the above this also includes a Vicon PiG kinematics clone. This makes the project completly independent from Vicon codebase, for full flexibility. | ||
- | ======PiG with functional centers/ | + | =====PiG with functional centers/ |
This project adds functional center/axes determination to the default Vicon PlugInGait model. It works together with the old **Vicon Workstation** and also with new Vicon **Nexus system**. | This project adds functional center/axes determination to the default Vicon PlugInGait model. It works together with the old **Vicon Workstation** and also with new Vicon **Nexus system**. | ||
- | Additional to the ScoRE/SARA functional method implementation of Vicon, several mathematical methods are available and the phases, which are used as input for the estimation, can be controlled by setting of events in the dynamic calibration trials. | + | Additional to the SCoRE/SARA functional method implementation of Vicon, several mathematical methods are available and the phases, which are used as input for the estimation, can be controlled by setting of events in the dynamic calibration trials. |
- | =====Eclipse entries===== | + | ====Eclipse entries==== |
To process the data, specific dynamic calibration trials must be done and its specific eclipse entries must be set: | To process the data, specific dynamic calibration trials must be done and its specific eclipse entries must be set: | ||
Zeile 31: | Zeile 33: | ||
{{ : | {{ : | ||
- | =====Modelparameter files===== | + | ====Modelparameter files==== |
Modelparameter-files are needed to read parameters from clinical measurements, | Modelparameter-files are needed to read parameters from clinical measurements, | ||
Zeile 46: | Zeile 48: | ||
$RTibialTorsion = -15 | $RTibialTorsion = -15 | ||
</ | </ | ||
+ | =====PiG with functional knee joint axes only ===== | ||
+ | |||
+ | This project adds functional knee joint axes determination (SARA) to the default Vicon PlugInGait model. It works together with the old Vicon Workstation system. | ||
+ | |||
+ | Additional to the SCoRE/SARA functional method implementation of Vicon Nexus, motion phases, which are used as input for the estimation, can be controlled by setting of events in the dynamic calibration trials. | ||
+ | |||
+ | ==== Preconditions ==== | ||
+ | * It is assumed, that the Vicon PiG is processed before processing with this model. | ||
+ | * Additional markers on the theigh are needed. Have a look at the follwing picture with the markerset | ||
+ | * Specific dynamic calibration movement with knee flexion. | ||
+ | * Specific eclipse entries. Have a look at the following table and screenshot | ||
+ | |||
+ | ==== Markerset ==== | ||
+ | |||
+ | {{ : | ||
+ | ====Eclipse entries==== | ||
+ | To process the data, specific dynamic calibration trials must be done and its specific eclipse entries must be set: | ||
+ | |||
+ | ^ Name ^ Value ^ Description ^ | ||
+ | ^ CLASS | Static_Cal | Static standing trial with knee alignment device. | | ||
+ | ^ CLASS | HipFlex/Ext | Flexion/ | ||
+ | ^ SIDE | Side R, Side L, bds | | | ||
+ | |||
+ | {{ : | ||
+ | |||
+ |