 This project adds functional knee joint axes determination (SARA) only to the default Vicon PlugInGait model. It works together with the old Vicon Workstation system and allows to control the usage of the motion phases which are used for the estimation by setting of events. This project adds functional knee joint axes determination (SARA) only to the default Vicon PlugInGait model. It works together with the old Vicon Workstation system and allows to control the usage of the motion phases which are used for the estimation by setting of events.
- 
-In the gait trials the lateral knee markers are projected onto the functional knee joint axes and the knee joint center is determined based on the clinical measurement of the knee width. Than the femur coordinate system is constructed equivalent to the original PiG. Keep in mind that this coordinate system does not have the functional axis as one of its axes. The axes are defined by cross products and have the longitudinal femur axes included. 
  
 ==== Preconditions ==== ==== Preconditions ====
-  * It is assumed, that the Vicon PiG is processed for the static calibration trial and all gait trials, before processing with this model. Vicon PiG Processing is not needed for the dynamic calibration trials+  * It is assumed, that the Vicon PiG is processed before processing with this model. 
-  * Additional markers on the theigh are needed. Have a look at the follwing markerset picture +  * Additional markers on the theigh are needed. Have a look at the follwing picture with the markerset 
-  * Specific dynamic calibration movement with knee flexion, events to define the phases used by the estimation.+  * Specific dynamic calibration movement with knee flexion.
   * Specific eclipse entries. Have a look at the following table and screenshot   * Specific eclipse entries. Have a look at the following table and screenshot
  
 ==== Markerset ==== ==== Markerset ====
  
-{{ :markerset.png?400 |}}+{{ :markerset.png?600 |}}
 ====Eclipse entries==== ====Eclipse entries====
-To process the data, specific dynamic calibration trials must be available and its specific eclipse entries must be set:+To process the data, specific dynamic calibration trials must be done and its specific eclipse entries must be set: 
 + 
 +^ Name ^ Value ^ Description ^ 
 +^ CLASS | Static_Cal | Static standing trial with knee alignment device. | 
 +^ CLASS | HipFlex/Ext | Flexion/Extention of the hip, which should cause also flexion/extention of the knee; last is used for knee-axis estimation; so it is important, that in this trial also the knee is flexed at minimum of 30 degrees RoM. | 
 +^ SIDE | Side R, Side L, bds | |
  
-^ Trial ^ Name ^ Value ^ Description ^ 
-^ 1 |  CLASS | Static_Cal | Static standing trial with knee alignment device. | 
-^ 2 |  CLASS | HipFlex/Ext | Flexion/Extention of the hip, which should cause also flexion/extention of the knee; last is used for knee-axis estimation; so it is important, that in this trial also the knee is flexed at minimum of 30 degrees RoM. | 
-^ all trials | SIDE | Side R, Side L, bds | | 
-^ 3-n | CLASS | Dynamic or Dynamic+Kinetics | Trial with gait, Strides defined by events. | 
 {{ :eclipse_functionalpig_54662.png?800 |}} {{ :eclipse_functionalpig_54662.png?800 |}}
- 
-====Modelparameter files==== 
-Modelparameter-files are needed to read parameters from clinical measurements, which are used to define offset angles in the kinematics model.  
- 
-There is an important limitation in the mechanism to work with these files: You can have an mp-file only for each session and not for each group. That is why the mp-files are found only, if they are saved in the session and not in the group. Details of working with .mp-files and its limitations you can find [[http://nimue-platform.motion-science.org/doku.php?id=glue:vicon&#mp-files|here]]. 
- 
-Used parameters are: 
- 
-<code> 
-$LKneeWidth = 103  
-$RKneeWidth = 104  
-</code> 
  
  
projects.txt · Zuletzt geändert: 2024/05/01 12:28 von 3.141.47.221