Hier werden die Unterschiede zwischen zwei Versionen angezeigt.
Beide Seiten der vorigen Revision Vorhergehende Überarbeitung Nächste Überarbeitung | Vorhergehende Überarbeitung Nächste Überarbeitung Beide Seiten der Revision | ||
projects [2022/08/15 05:41] 167.114.64.97 alte Version wiederhergestellt (2021/09/24 13:36) |
projects [2024/03/28 11:50] 47.128.53.245 alte Version wiederhergestellt (2023/11/21 18:23) |
||
---|---|---|---|
Zeile 1: | Zeile 1: | ||
======Projects====== | ======Projects====== | ||
- | A folder with subfolders which includes a set of xml-files to describe what to do with a dataset (session, a set of trials, typcially with c3d-files) is called a " | + | A folder with subfolders which includes a set of xml-files to describe what to do with a dataset (session, a set of trials, typcially with c3d-files) is called a " |
=====PiGMo10 Vicon PiG based===== | =====PiGMo10 Vicon PiG based===== | ||
Zeile 50: | Zeile 50: | ||
=====PiG with functional knee joint axes only ===== | =====PiG with functional knee joint axes only ===== | ||
- | This project adds functional knee joint axes determination (SARA) only to the default Vicon PlugInGait model. It works together with the old Vicon Workstation system and allows to control the usage of the motion phases, which are used for the estimation by setting of events. | + | This project adds functional knee joint axes determination (SARA) only to the default Vicon PlugInGait model. It works together with the old Vicon Workstation system and allows to control the usage of the motion phases which are used for the estimation by setting of events. |
- | In the gait trials the lateral knee markers are projected onto the functional knee joint axes and the knee joint center is determined based on the clinical measurement of the knee width. Than the femur coordinate system is constructed equivalent to the original PiG. Keep in mind that this coordinate system does not have the functional axis as one of its axes. The axes are defined by cross products | + | In the gait trials the lateral knee markers are projected onto the functional knee joint axes and the knee joint center is determined based on the clinical measurement of the knee width. Than the femur coordinate system is constructed equivalent to the original PiG. Keep in mind that this coordinate system does not have the functional axis as one of its axes. The axes are defined by cross products and have the longitudinal femur axes included. |
- | + | ||
- | The proximal tibia (anatomical) coordinate systems are defined by PiG virtual markers. | + | |
==== Preconditions ==== | ==== Preconditions ==== | ||
Zeile 71: | Zeile 69: | ||
^ 1 | CLASS | Static_Cal | Static standing trial with knee alignment device. | | ^ 1 | CLASS | Static_Cal | Static standing trial with knee alignment device. | | ||
^ 2 | CLASS | HipFlex/Ext | Flexion/ | ^ 2 | CLASS | HipFlex/Ext | Flexion/ | ||
- | ^ all trials | SIDE | Side R, Side L, bds | Hip/ | + | ^ all trials | SIDE | Side R, Side L, bds | | |
^ 3-n | CLASS | Dynamic or Dynamic+Kinetics | Trial with gait, Strides defined by events. | | ^ 3-n | CLASS | Dynamic or Dynamic+Kinetics | Trial with gait, Strides defined by events. | | ||
{{ : | {{ : | ||
Zeile 87: | Zeile 85: | ||
</ | </ | ||
- | ==== Output ==== | ||
- | |||
- | In the default configuration the output is written into " | ||
- | |||
- | Hip- and knee-angles are saved to its corresponding PiG angles with the same names but based on the functional knee joint axes. | ||
- | |||
- | ^ Name ^ Description ^ | ||
- | ^ R/ | ||
- | ^ R/ | ||
- | |||
- | You can change the output behavoir in the calcml.xml file in the subfolder " | ||
- | |||
- | <code xml> | ||
- | < | ||
- | < | ||
- | <entry key=" | ||
- | < | ||
- | </ | ||
- | < | ||
- | <entry key=" | ||
- | <entry key=" | ||
- | </ | ||
- | <input labelset=" | ||
- | < | ||
- | </ | ||
- | <output labelset=" | ||
- | handlerclass=" | ||
- | </ | ||
- | < | ||
- | </ | ||
- | </ | ||
- | |||
- | In this code snipset the the output is done by the " | ||
- | |||
- | <code xml> | ||
- | <?xml version=" | ||
- | |||
- | < | ||
- | xmlns: | ||
- | xsi: | ||
- | name=" | ||
- | |||
- | <!-- text/ | ||
- | <Labels name=" | ||
- | ... | ||
- | </ | ||
- | ==== Process Log ==== | ||
- | The logging output is shown in a seperate window typically shown at the buttom of the application. If this window is not shown you can reopen it by the corresponding action in the Windows-main-menu. | ||
- | |||
- | The following picture shows a part of the logging output of processing a session. The messages in black are only for information. The blue ones are warning. If there are red ones, something is totally wrong. | ||
- | |||
- | {{ : | ||
- | |||
- | You can see Intervals of frames defined by start- and end-frame enclosed in "[ ; ]". In these intervals the calculation cauld not be done. Typically the origin of this are unlabled markers. You should go to Vicon Worstation to check this. | ||
- | The information about the differences between PiG and functional PiG, given as an direction cosine angle between the corresponding two knee joint axes is print in blue but typically there is nothing wrong. But you should always have a look at it. If the differences is hight you should think about if this can be correct. |