Hier werden die Unterschiede zwischen zwei Versionen angezeigt.
Beide Seiten der vorigen Revision Vorhergehende Überarbeitung Nächste Überarbeitung | Vorhergehende Überarbeitung Nächste Überarbeitung Beide Seiten der Revision | ||
projects [2022/01/18 09:07] 2a01:4f8:190:6194::2 alte Version wiederhergestellt (2021/07/30 23:00) |
projects [2024/04/26 18:10] 185.215.165.249 alte Version wiederhergestellt (2023/07/29 15:04) |
||
---|---|---|---|
Zeile 1: | Zeile 1: | ||
- | ======PiGMo10 Vicon PiG based====== | + | ======Projects====== |
+ | A folder with subfolders which includes a set of xml-files to describe what to do with a dataset (session, a set of trials, typcially with c3d-files) is called a " | ||
+ | =====PiGMo10 Vicon PiG based===== | ||
This is a clone of what the PiGMo10 " | This is a clone of what the PiGMo10 " | ||
Zeile 5: | Zeile 7: | ||
So the complete pipeline from the raw data, to the sheets up to the exported hd-asc files, used by **HeiDataProVIT**, | So the complete pipeline from the raw data, to the sheets up to the exported hd-asc files, used by **HeiDataProVIT**, | ||
- | Only some testing and finetuning, to make the pipeline more robust, is need for daily usage. | + | Extensive |
- | ======PiGMo10 | + | The lower body kinematics angles of this project are described [[http:// |
+ | =====PiGMo10 | ||
- | Additional to the above this also includes a Vicon PiG kinematics clone. This makes the project completly independent from Vicon for full flexibility. | + | Additional to the above this also includes a Vicon PiG kinematics clone. This makes the project completly independent from Vicon codebase, |
- | ======Gait with functional centers/ | + | =====PiG with functional centers/ |
This project adds functional center/axes determination to the default Vicon PlugInGait model. It works together with the old **Vicon Workstation** and also with new Vicon **Nexus system**. | This project adds functional center/axes determination to the default Vicon PlugInGait model. It works together with the old **Vicon Workstation** and also with new Vicon **Nexus system**. | ||
- | Additional to the ScoRE/SARA functional method implementation of Vicon, several mathematical methods are available and the phases, which are used as input for the estimation, can be controlled by setting of events in the dynamic calibration trials. | + | Additional to the SCoRE/SARA functional method implementation of Vicon, several mathematical methods are available and the phases, which are used as input for the estimation, can be controlled by setting of events in the dynamic calibration trials. |
- | =====Eclipse entries===== | + | ====Eclipse entries==== |
To process the data, specific dynamic calibration trials must be done and its specific eclipse entries must be set: | To process the data, specific dynamic calibration trials must be done and its specific eclipse entries must be set: | ||
Zeile 30: | Zeile 33: | ||
{{ : | {{ : | ||
- | =====Modelparameter files===== | + | ====Modelparameter files==== |
Modelparameter-files are needed to read parameters from clinical measurements, | Modelparameter-files are needed to read parameters from clinical measurements, | ||
Zeile 45: | Zeile 48: | ||
$RTibialTorsion = -15 | $RTibialTorsion = -15 | ||
</ | </ | ||
+ | =====PiG with functional knee joint axes only ===== | ||
+ | |||
+ | This project adds functional knee joint axes determination (SARA) only to the default Vicon PlugInGait model. It works together with the old Vicon Workstation system and allows to control the usage of the motion phases, which are used for the estimation by setting of events. | ||
+ | |||
+ | In the gait trials the lateral knee markers are projected onto the functional knee joint axes and the knee joint center is determined based on the clinical measurement of the knee width. Than the femur coordinate system is constructed equivalent to the original PiG. Keep in mind that this coordinate system does not have the functional axis as one of its axes. The axes are defined by cross products and have the longitudinal femur axes included. | ||
+ | |||
+ | The proximal tibia (anatomical) coordinate systems are defined by PiG virtual markers. | ||
+ | |||
+ | ==== Preconditions ==== | ||
+ | * It is assumed, that the Vicon PiG is processed for the static calibration trial and all gait trials, before processing with this model. Vicon PiG processing is not needed for the dynamic calibration trials. | ||
+ | * Additional markers on the shank are needed. Have a look at the follwing markerset picture | ||
+ | * Specific dynamic calibration movements with knee flexion; events to define the phases used by the estimation. | ||
+ | * Specific eclipse entries. Have a look at the following table and screenshot. | ||
+ | |||
+ | ==== Markerset ==== | ||
+ | |||
+ | {{ : | ||
+ | ====Eclipse entries==== | ||
+ | To process the data, specific dynamic calibration trials must be available and its specific eclipse entries must be set: | ||
+ | |||
+ | ^ Trial ^ Name ^ Value ^ Description ^ | ||
+ | ^ 1 | CLASS | Static_Cal | Static standing trial with knee alignment device. | | ||
+ | ^ 2 | CLASS | HipFlex/Ext | Flexion/ | ||
+ | ^ all trials | SIDE | Side R, Side L, bds | Hip/ | ||
+ | ^ 3-n | CLASS | Dynamic or Dynamic+Kinetics | Trial with gait, Strides defined by events. | | ||
+ | {{ : | ||
+ | |||
+ | ====Modelparameter files==== | ||
+ | Modelparameter-files are needed to read parameters from clinical measurements, | ||
+ | |||
+ | There is an important limitation in the mechanism to work with these files: You can have an mp-file only for each session and not for each group. That is why the mp-files are found only, if they are saved in the session and not in the group. Details of working with .mp-files and its limitations you can find [[http:// | ||
+ | |||
+ | Used parameters are: | ||
+ | |||
+ | < | ||
+ | $LKneeWidth = 103 | ||
+ | $RKneeWidth = 104 | ||
+ | </ | ||
+ | |||
+ | ==== Output ==== | ||
+ | |||
+ | In the default configuration the output is written into " | ||
+ | |||
+ | Hip- and knee-angles are saved to its corresponding PiG angles with the same names but based on the functional knee joint axes. | ||
+ | |||
+ | ^ Name ^ Description ^ | ||
+ | ^ R/ | ||
+ | ^ R/ | ||
+ | |||
+ | ==== Process Log ==== | ||
+ | The following picture shows a part of the logging output of processing a session. The messages in black are only for information. The blue ones are warning. If there are red ones, something is totally wrong. | ||
+ | |||
+ | {{ : | ||
+ | |||
+ | You can see Intervals of frames defined by start- and end-frame enclosed in "[ ; ]". In these intervals the calculation cauld not be done. Typically the origin of this are unlabled markers. You should go to Vicon Worstation to check this. |