Hier werden die Unterschiede zwischen zwei Versionen angezeigt.
Beide Seiten der vorigen Revision Vorhergehende Überarbeitung Nächste Überarbeitung | Vorhergehende Überarbeitung Nächste Überarbeitung Beide Seiten der Revision | ||
projects [2024/04/23 15:48] 135.181.212.177 alte Version wiederhergestellt (2023/03/11 13:13) |
projects [2024/05/06 09:07] 47.128.21.169 alte Version wiederhergestellt (2021/07/10 15:32) |
||
---|---|---|---|
Zeile 50: | Zeile 50: | ||
=====PiG with functional knee joint axes only ===== | =====PiG with functional knee joint axes only ===== | ||
- | This project adds functional knee joint axes determination (SARA) to the default Vicon PlugInGait model. It works together with the old Vicon Workstation system. | + | This project adds functional knee joint axes determination (SARA) |
- | + | ||
- | Additional | + | |
==== Preconditions ==== | ==== Preconditions ==== | ||
* It is assumed, that the Vicon PiG is processed before processing with this model. | * It is assumed, that the Vicon PiG is processed before processing with this model. | ||
- | * Additional markers on the theigh are needed. Have a look at the follwing | + | * Additional markers on the theigh are needed. Have a look at the follwing markerset |
- | * Specific dynamic calibration movement with knee flexion. | + | * Specific dynamic calibration movement with knee flexion, events to define the phases used by the estimation. |
* Specific eclipse entries. Have a look at the following table and screenshot | * Specific eclipse entries. Have a look at the following table and screenshot | ||
==== Markerset ==== | ==== Markerset ==== | ||
- | {{ : | + | {{ : |
====Eclipse entries==== | ====Eclipse entries==== | ||
- | To process the data, specific dynamic calibration trials must be done and its specific eclipse entries must be set: | + | To process the data, specific dynamic calibration trials must be available |
- | + | ||
- | ^ Name ^ Value ^ Description ^ | + | |
- | ^ CLASS | Static_Cal | Static standing trial with knee alignment device. | | + | |
- | ^ CLASS | HipFlex/Ext | Flexion/ | + | |
- | ^ SIDE | Side R, Side L, bds | | | + | |
+ | ^ Trial ^ Name ^ Value ^ Description ^ | ||
+ | ^ 1 | CLASS | Static_Cal | Static standing trial with knee alignment device. | | ||
+ | ^ 2 | CLASS | HipFlex/Ext | Flexion/ | ||
+ | ^ all trials | SIDE | Side R, Side L, bds | | | ||
+ | ^ 3-n | CLASS | Dynamic or Dynamic+Kinetics | Trial with gait, Strides defined by events. | | ||
{{ : | {{ : | ||