Hier werden die Unterschiede zwischen zwei Versionen angezeigt.
Beide Seiten der vorigen Revision Vorhergehende Überarbeitung Nächste Überarbeitung | Vorhergehende Überarbeitung | ||
projects [2024/04/24 05:09] 47.128.51.80 alte Version wiederhergestellt (2023/10/09 07:24) |
projects [2024/05/06 06:42] (aktuell) 47.128.25.10 alte Version wiederhergestellt (2023/10/11 05:50) |
||
---|---|---|---|
Zeile 32: | Zeile 32: | ||
{{ : | {{ : | ||
- | |||
- | ====Modelparameter files==== | ||
- | Modelparameter-files are needed to read parameters from clinical measurements, | ||
- | |||
- | There is an important limitation in the mechanism to work with these files: You can have an mp-file only for each session and not for each group. That is why the mp-files are found only, if they are saved in the session and not in the group. Details of working with .mp-files and its limitations you can find [[http:// | ||
- | |||
- | Used parameters are: | ||
- | |||
- | < | ||
- | $LKneeWidth = 103 | ||
- | $LAnkleWidth = 71 | ||
- | $LTibialTorsion = -15 | ||
- | $RKneeWidth = 104 | ||
- | $RAnkleWidth = 71 | ||
- | $RTibialTorsion = -15 | ||
- | </ | ||
=====PiG with functional knee joint axes only ===== | =====PiG with functional knee joint axes only ===== | ||
- | This project adds functional knee joint axes determination (SARA) | + | This project adds functional knee joint axes determination (SARA) to the default Vicon PlugInGait model. It works together with the old Vicon Workstation system. |
- | ==== Preconditions ==== | + | Additional to the SCoRE/SARA functional method implementation of Vicon Nexus, motion phases, which are used as input for the estimation, can be controlled by setting of events |
- | * It is assumed, that the Vicon PiG is processed before processing with this model. | + | |
- | * Additional markers on the theigh | + | |
- | * Specific dynamic calibration movement with knee flexion, events | + | |
- | * Specific eclipse entries. Have a look at the following table and screenshot | + | |
- | ==== Markerset | + | ====Eclipse entries==== |
+ | To process the data, specific dynamic calibration trials must be done and its specific eclipse entries must be set: | ||
- | {{ :markerset.png? | + | ^ Name ^ Value ^ Description ^ |
- | ====Eclipse entries==== | + | ^ CLASS | Static_Cal | Static standing trial with knee alignment device. | |
- | To process | + | ^ CLASS | HipFlex/Ext | Flexion/ |
+ | ^ SIDE | Side R, Side L, bds | | | ||
- | ^ Trial ^ Name ^ Value ^ Description ^ | ||
- | ^ 1 | CLASS | Static_Cal | Static standing trial with knee alignment device. | | ||
- | ^ 2 | CLASS | HipFlex/Ext | Flexion/ | ||
- | ^ all trials | SIDE | Side R, Side L, bds | | | ||
- | ^ 3-n | CLASS | Dynamic or Dynamic+Kinetics | Trial with gait, Strides defined by events. | | ||
{{ : | {{ : | ||