Benutzer-Werkzeuge

Webseiten-Werkzeuge


projects

Unterschiede

Hier werden die Unterschiede zwischen zwei Versionen angezeigt.

Link zu dieser Vergleichsansicht

Beide Seiten der vorigen Revision Vorhergehende Überarbeitung
Nächste Überarbeitung
Vorhergehende Überarbeitung
projects [2024/04/24 05:09]
47.128.51.80 alte Version wiederhergestellt (2023/10/09 07:24)
projects [2024/05/06 06:42] (aktuell)
47.128.25.10 alte Version wiederhergestellt (2023/10/11 05:50)
Zeile 32: Zeile 32:
  
 {{ :eclipse_functionalpig_54662.png?800 |}} {{ :eclipse_functionalpig_54662.png?800 |}}
- 
-====Modelparameter files==== 
-Modelparameter-files are needed to read parameters from clinical measurements, which are used to define offset angles in the kinematics model.  
- 
-There is an important limitation in the mechanism to work with these files: You can have an mp-file only for each session and not for each group. That is why the mp-files are found only, if they are saved in the session and not in the group. Details of working with .mp-files and its limitations you can find [[http://nimue-platform.motion-science.org/doku.php?id=glue:vicon&#mp-files|here]]. 
- 
-Used parameters are: 
- 
-<code> 
-$LKneeWidth = 103  
-$LAnkleWidth = 71 
-$LTibialTorsion = -15 
-$RKneeWidth = 104  
-$RAnkleWidth = 71 
-$RTibialTorsion = -15 
-</code> 
 =====PiG with functional knee joint axes only ===== =====PiG with functional knee joint axes only =====
  
-This project adds functional knee joint axes determination (SARA) only to the default Vicon PlugInGait model. It works together with the old Vicon Workstation system and allows to control the usage of the motion phases which are used for the estimation by setting of events.+This project adds functional knee joint axes determination (SARA) to the default Vicon PlugInGait model. It works together with the old Vicon Workstation system.
  
-==== Preconditions ==== +Additional to the SCoRE/SARA functional method implementation of Vicon Nexus, motion phases, which are used as input for the estimationcan be controlled by setting of events in the dynamic calibration trials.
-  * It is assumed, that the Vicon PiG is processed before processing with this model. +
-  * Additional markers on the theigh are needed. Have a look at the follwing markerset picture +
-  * Specific dynamic calibration movement with knee flexion, events to define the phases used by the estimation. +
-  * Specific eclipse entries. Have a look at the following table and screenshot+
  
-==== Markerset ====+====Eclipse entries==== 
 +To process the data, specific dynamic calibration trials must be done and its specific eclipse entries must be set:
  
-{{ :markerset.png?400 |}} +^ Name ^ Value ^ Description ^ 
-====Eclipse entries==== +^ CLASS | Static_Cal | Static standing trial with knee alignment device. | 
-To process the dataspecific dynamic calibration trials must be available and its specific eclipse entries must be set:+^ CLASS | HipFlex/Ext | Flexion/Extention of the hipwhich should cause also flexion/extention of the knee; last is used for knee-axis estimation; so it is important, that in this trial also the knee is flexed at minimum of 30 degrees RoM. | 
 +^ SIDE | Side R, Side L, bds | |
  
-^ Trial ^ Name ^ Value ^ Description ^ 
-^ 1 |  CLASS | Static_Cal | Static standing trial with knee alignment device. | 
-^ 2 |  CLASS | HipFlex/Ext | Flexion/Extention of the hip, which should cause also flexion/extention of the knee; last is used for knee-axis estimation; so it is important, that in this trial also the knee is flexed at minimum of 30 degrees RoM. | 
-^ all trials | SIDE | Side R, Side L, bds | | 
-^ 3-n | CLASS | Dynamic or Dynamic+Kinetics | Trial with gait, Strides defined by events. | 
 {{ :eclipse_functionalpig_54662.png?800 |}} {{ :eclipse_functionalpig_54662.png?800 |}}
  
  
projects.1713928188.txt.gz · Zuletzt geändert: 2024/04/24 05:09 von 47.128.51.80